CAN Verified closed-loop confidence: high
- Protocol
- Victron BMS-Can
- Inverter setting
- GX: BMS-Can (500 kbit/s); connecting WeCo force-enables DVCC+SVS and disables STS; GX FW ≥ v3.31; a VE.Can RJ45 terminator is required
- Battery / DIP
- WeCo-supplied comms cable; battery pin1 CAN-H → Victron pin7, pin2 CAN-L → pin8, pin3 GND → pin3 (Type-B side)
Cable
WeCo ↔ Victron GX (WeCo-supplied cable; a VE.Can RJ45 terminator is mandatory)
BMS-Can 500 kbit/s
A missing VE.Can terminator ⇒ the battery is not detected.
Known errors
| Code | Cause | Fix |
|---|---|---|
| Battery not shown in GX | No VE.Can terminator, or CAN rate not 500 kbit/s | Fit the RJ45 terminator and set 500 kbit/s |