ESS Compat

Victron Energy MultiPlus-II 48/5000 + WeCo 5K3

Closed-loop compatibility, protocol setting and cabling. Best status: verified closed loop.

Field-sourced data. Verify against the current official manual and firmware before commissioning — a wrong setting can damage equipment.

CAN Verified closed-loop confidence: high
Protocol
Victron BMS-Can
Inverter setting
GX: BMS-Can (500 kbit/s); connecting WeCo force-enables DVCC+SVS and disables STS; GX FW ≥ v3.31; a VE.Can RJ45 terminator is required
Battery / DIP
WeCo-supplied comms cable; battery pin1 CAN-H → Victron pin7, pin2 CAN-L → pin8, pin3 GND → pin3 (Type-B side)

Cable

WeCo ↔ Victron GX (WeCo-supplied cable; a VE.Can RJ45 terminator is mandatory)

BMS-Can 500 kbit/s

A missing VE.Can terminator ⇒ the battery is not detected.

Known errors

CodeCauseFix
Battery not shown in GX No VE.Can terminator, or CAN rate not 500 kbit/s Fit the RJ45 terminator and set 500 kbit/s

Sources

Get the right parts
Comm cable / adapter5K3MultiPlus-II 48/5000

As an affiliate we may earn a commission from qualifying purchases, at no extra cost to you. This does not affect the compatibility data above.

advertisement

All batteries for MultiPlus-II 48/5000 →