CAN Verified closed-loop confidence: high
- Protocol
- Victron BMS-Can
- Inverter setting
- GX: VE.Can Profile = CAN-bus BMS (500 kbit/s); DVCC on; GX FW ≥ v2.52; always terminate the GX CAN port; Lithium (Abs 55 V / Float 54.8 V / 1 h)
- Battery / DIP
- Victron Type-B cable (ASS030720018); master/address DIP per the BSLBATT + Victron setup guide
Cable
BSLBATT ↔ Victron GX (Victron Type-B cable, ASS030720018)
CAN-bus BMS 500 kbit/s