Sol-Ark Sol-Ark 15K + Fortress Power eVault Max 18.5
Closed-loop compatibility, protocol setting and cabling. Best status: verified closed loop.
Field-sourced data. Verify against the current official manual and firmware before commissioning — a wrong setting can damage equipment.
RS485 Verified closed-loop confidence: high
- Protocol
- Modbus (RS485)
- Inverter setting
- Battery menu → BMS Lithium Batt 04 (BMS in control); comms into the Sol-Ark port labelled Battery/CANBUS; battery end into the master eVault RS485 port
- Battery / DIP
- eVault DIP ON for end batteries, OFF for middle; Battery ID sequential (0 if single); Protocol ID = 1 (Sol-Ark)
Cable
Fortress eVault ↔ Sol-Ark (directional crossover: eVault pins 3+5+6 → Sol-Ark pins 6+7+8; pre-made cable ships from 03/2022)
Modbus RS485, custom 3+5+6→6+7+8
This pair is RS485/Modbus even though the Sol-Ark port is labelled 'CANBUS'.
Known errors
| Code | Cause | Fix |
|---|---|---|
| No battery data on line 2 | Wrong cable direction / Protocol ID / DIP | Set Protocol ID 1; DIP ON at chain ends; follow the cable labels — a battery data line appears when linked |
Sources
Get the right parts
As an affiliate we may earn a commission from qualifying purchases, at no extra cost to you. This does not affect the compatibility data above.
advertisement